Home > Customized

Dyna-Glo Heater Parts Won’t Light or Stay Lit. 10 Quick Fixes To Try

Check The Thermocouple On Your Dyna-Glo Heater

Is your Dyna-Glo heater struggling to stay lit or repeatedly shutting off? Don’t panic – with a few simple troubleshooting steps, you can likely get it working again. One of the most common issues with propane heaters like Mr. Heater, Dyna-Glo, and Ventless models is a faulty thermocouple.

The thermocouple is a small metallic device that sits in the pilot light flame. It generates a tiny electrical signal that tells the gas valve to remain open and allow propane to keep flowing to the burner. If the pilot light goes out, the thermocouple cools off and stops producing the electrical signal, shutting off the gas valve for safety.

Over time, thermocouples can corrode or get coated in debris, interrupting their ability to detect the pilot flame. Give yours a visual inspection first. If it looks damaged or dirty, try cleaning it gently with emery cloth or fine sandpaper. Be careful not to damage the wires. If cleaning doesn’t help, replacement thermocouples are inexpensive and widely available for models like the Dyna-Glo. Follow the manufacturer instructions to remove and replace it.

Verify Proper Thermocouple Positioning

Dyna-Glo Heater Parts Won

A thermocouple that isn’t positioned in the very tip of the pilot flame may fail to generate a strong enough electrical signal. Ensure yours is seated firmly in the flame. Adjust the pilot light alignment if needed so that the flame envelops 3/8″ to 1/2″ of the thermocouple’s length.

Check Thermocouple Output Voltage

Use a multimeter to check that your thermocouple is producing at least 15 millivolts when heated by the pilot flame. If not, it needs replacement. An older worn thermocouple may still register some voltage but not enough to hold the gas valve open.

Inspect Thermocouple Wiring

Faulty wire connections can also interrupt the thermocouple voltage signal. Check that the thermocouple leads are securely fastened to the gas valve terminals. Look for any visibly damaged wires and replace them if needed. Clean the connections with emery cloth to remove corrosion.

Does Your Dyna-Glo Heater Need A New Igniter?

If your propane heater won’t spark at all when you turn it on, the igniter is likely faulty. Dyna-Glo and other brands use a pilot flame igniter to light the heater. When powered, it generates an electric spark to ignite the gas.

Igniters deteriorate over time from the repeated sparking. Eventually they stop working altogether. Replacement igniter assemblies are easy to find online or at hardware stores. Just be sure to get the right one for your heater make and model.

Inspect The Igniter Visually

Dyna-Glo Heater Parts Won

Closely examine the igniter tip where sparks are produced. Look for any cracks, damage or erosion that could prevent sparking. The tip should be intact with defined edges.

Check Igniter Resistance

Use a multimeter to check the igniter resistance. Consult your owner’s manual for the proper range. Typical values are between 40 to 300 ohms. If out of spec, replace the igniter.

Ensure Proper Igniter Positioning

For reliable lighting, the igniter tip must be precisely positioned within 1/8″ of the pilot hood opening. If improperly aligned, no spark will occur. Gently bend the igniter assembly as needed to achieve the correct gap distance.

With just a bit of troubleshooting know-how, you can likely get your temperamental Dyna-Glo heater back up and running. Start with an inspection of the thermocouple and igniter components. Replace if needed. And be sure to consult your owner’s manual for full maintenance procedures. With proper care, your heater will provide cozy warmth for years to come.

Does Your Dyna-Glo Heater Need A New Igniter?

Nothing’s more frustrating than flipping the switch on your trusty Dyna-Glo heater only to hear an unsatisfying empty click. No glow of fiery warmth to chase away the cold. Yep, it seems your ignition system is on the fritz.

Before you toss the whole thing out in a frosty rage, take a deep breath. In most cases, the culprit is a simple faulty igniter that just needs replacing. With a few basic troubleshooting tips, you can get that pilot lit and be basking in toasty heat once again.

How Do Propane Heater Igniters Work?

Heaters like the Dyna-Glo use a pilot light combined with an electric igniter to get the party started. When powered on, the igniter generates a spark to light the pilot flame. The thermocouple senses the pilot is lit, signaling the valve to open and allow gas flow to the burner. Voila, ignition success!

The repeated sparking slowly degrades the igniter over time until it fails to spark at all. The good news is replacement igniter assemblies are inexpensive and widely available online or at your local hardware store. But first, let’s run through some quick troubleshooting checks.

Give The Igniter Tip A Visual Inspection

Dyna-Glo Heater Parts Won

Closely examine where the sparks are produced on the igniter tip. Look for any cracks, damage or excessive wear that could prevent normal sparking operation. The tip should have well-defined edges and be intact.

If the tip looks really gnarly, replacement is probably your best bet. Over time, tiny electrode gaps in the tip can widen through erosion, weakening the sparking potential.

Ensure Proper Igniter Positioning

For reliable ignition, precise positioning matters. The igniter tip should be 1/8″ or less from the pilot hood opening. Over time it can get bumped or drift out of alignment. Gently bend the assembly as needed to achieve the optimal tiny gap distance.

Check The Igniter Resistance Value

Use a multimeter to check the igniter resistance. Consult your owner’s manual for the proper range – often between 40 to 300 ohms. If the reading falls outside the specified range, replacement is required.

Inspect The Igniter Wiring

Like any electrical component, faulty wiring can cause ignition failure. Check that the igniter wire leads are securely attached to the gas valve terminals. Look for fraying or damage. Ensure connections are tight and free of corrosion.

If you’ve triple checked all that but still nothing, the igniter itself is likely shot. Time for a replacement. Installation is usually straightforward – just swap in the new igniter and hook up the wiring. Have that Dyna-Glo glowing warm in no time.

With the huge selection of replacement parts available today for brands like Mr Heater, Ventless, Dyna-Glo, Kozy World, and more, there’s no need to scrap a broken heater. A simple igniter swap can restore performance and have you enjoying reliable warmth all winter long.

Clean The Burner And Orifices On Your Glo Warm Heater

Dyna-Glo Heater Parts Won

Is your trusty Glo Warm heater sputtering, backfiring, or struggling to ignite? Before calling the repairman, try giving the burner and orifices a good cleaning. Buildup of dust, lint, spiderwebs, and other debris is a common culprit behind poor heater performance.

The burner and orifice are precision engineered parts that work together to mix air and fuel for proper combustion. Even a small amount of gunk in the wrong place can disrupt airflow and lead to ignition issues. Thankfully, cleaning them is a pretty straightforward DIY task.

Why Proper Burner Cleaning Is Crucial

The burner assembly uses a set of small openings called orifices to meter the gas flow at just the right rate for efficient burning. Clogs or blockages in the orifices can cause backfires, excessive yellow tipping of the flames, and ignition problems.

The burner surface needs to be kept clear of debris so the flames can propagate cleanly across it. Obstructions here lead to uneven burning, hot spots, and poor heating performance.

Cleaning away dirt, dust, spiderwebs, lint, and other gunk restores your heater’s airflow and allows it to burn the way it was designed to. Think of it like changing the air filter in your furnace or AC.

How To Clean the Burner and Orifices

Cleaning your Glo Warm burner and orifices is quick and straightforward.

  1. Turn off the heater and allow it to fully cool.
  2. Detach the burner assembly from the heater body.
  3. Use compressed air to blow out debris from the burner surface and orifices.
  4. Scrub away any stuck-on gunk with a wire brush or pipe cleaner.
  5. Reinstall the cleaned burner assembly.

It’s a good idea to inspect the area around the pilot light as well while you have it opened up. Remove any dust or lint buildup so it can ignite properly. Performing this simple maintenance every year or so will keep your Glo Warm running in top form.

When To Replace a Damaged Burner

If the burner surface shows excessive pitting, warping, or large blocked ports, replacement may be needed. Over time the repeated heating and cooling can degrade the burner. Thankfully, replacements are readily available for most models, either online or from the manufacturer.

With just some simple cleaning maintenance, you can enjoy reliable warmth from your Glo Warm heater for years to come. Be sure to consult your owner’s manual for full procedures on properly disassembling, cleaning, and reassembling your specific model. Stay cozy!

Inspect The Fuel Line On Propane Heaters Like Mr. Heater

Dyna-Glo Heater Parts Won

Got an older propane heater that’s acting up? Before you scrap it, take a close look at the fuel line. Cracked, brittle, or obstructed fuel lines are a common culprit behind poor ignition and performance issues in aging heaters.

The fuel line carries propane from the tank to the control valve and burner. Like other rubber and plastic components, it slowly deteriorates over time. Thankfully, replacing a bad fuel line is a straightforward fix to get your heater running right again.

Warning Signs of a Faulty Fuel Line

Here are some telltale signs your fuel line needs attention:

  • The heater won’t light or stay lit
  • Faint propane smell from the line
  • Visible cracks, brittleness, or damage to the line
  • Kinks or flattened sections blocking fuel flow

On older heaters like the Mr. Heater models, inspect the line closely for cracks or dry rot. Turn it at different angles to check for internal kinks that could impede fuel flow.

How To Replace a Propane Heater Fuel Line

Dyna-Glo Heater Parts Won

Replacing a faulty fuel line is a straightforward DIY fix:

  1. Turn off propane at the tank and disconnect the line.
  2. Cut away the old line and remove it from the heater.
  3. Install the new replacement fuel line, securing with clamps.
  4. Check for leaks by soap testing connections.

Many universal fuel line repair kits are available online and at hardware stores. Just bring your old line to match up diameter and end fittings. Adding some flexible sections can help prevent future kinking.

Protect Your Fuel Line Investment

To maximize the life of your new fuel line:

  • Inspect it periodically for cracks or wear.
  • Keep it free of kinks by coiling excess line.
  • Avoid exposing it to chemicals or solvents.
  • Shield it from direct heat or abrasion from sharp objects.

With just an inexpensive fuel line replacement, you can restore that temperamental Mr. Heater or other propane unit to reliable performance. Just be sure to soap test for leaks and follow the manufacturer instructions for proper installation.

Make Sure The Gas Valve Is Working On Your Ventless Heater

Ventless propane heaters provide a great way to add supplemental warmth to enclosed spaces. But if yours is struggling to light or shuts off unexpectedly, the gas control valve may be faulty.

The valve regulates gas flow from the fuel line to the burner, controlled by the thermostat and safety sensors. Before replacing the whole unit, inspect this key component. A little troubleshooting and cleaning can often get a sticky valve back in working order.

How the Gas Valve Works

Ventless heater gas valves use a solenoid to open and close the fuel flow. When powered, the solenoid pulls up a plunger that allows propane to pass through to the burner. This provides on-demand heat control.

The valve also receives safety input from the thermocouple, oxygen depletion sensor, and tip-over switch. If any of those detect a hazardous condition, the valve shuts off all gas flow. This fails-safe design prevents deadly CO poisoning and explosions.

Signs of Gas Valve Problems

Dyna-Glo Heater Parts Won

Here are some common symptoms of faulty valve operation:

  • Heater won’t light
  • Burner ignites but shuts off soon after
  • Burner only ignites on low setting
  • Valve emits buzzing/humming noise

If the safety sensors check out okay, the valve itself is likely malfunctioning and needs further inspection.

Troubleshooting the Gas Valve

First, remove any debris, dirt, or corrosion from the valve housing and electrical connections. Then:

  1. Check for correct gas input pressure and voltage to the valve.
  2. Listen for solenoid clicking when powered on/off.
  3. Test operation in manual mode by overriding solenoid.

If problems persist, replacement gas valve kits are readily available for most ventless heater models. Just be sure to use a factory authorized part to maintain safety certifications.

With a properly functioning gas valve, your ventless propane heater will provide efficient on-demand warmth right when you need it. Stay cozy this winter!

Replace The Thermocouple On Torpedo Heaters And Garage Heaters

Dyna-Glo Heater Parts Won

If your trusty torpedo or garage propane heater keeps shutting off unexpectedly, the thermocouple likely needs replacement. This small component plays a crucial safety role in monitoring the pilot flame.

The thermocouple generates a tiny voltage when heated by the pilot light, signaling the gas valve to remain open. If the pilot goes out, the dropped voltage causes the valve to automatically cut off the gas supply. This prevents raw fuel from continuously pouring out if ignition fails.

Over time, thermocouples wear out through corrosion and thermal stress. Replacing a faulty one can often get finicky heaters running right again.

Warning Signs of Thermocouple Issues

Here are some common symptoms of a failing thermocouple:

  • Heater constantly shuts off soon after lighting
  • Pilot light goes out frequently
  • Corroded or cracked thermocouple tip
  • Weak millivolt output from thermocouple

If your heater exhibits any of these, it’s likely time to swap in a fresh thermocouple.

Replacing the Thermocouple

New replacement thermocouples are inexpensive and widely available at hardware stores or online. Here are the basic steps for installation:

  1. Turn off gas supply and allow heater to cool completely.
  2. Remove old thermocouple from gas valve and detach leads.
  3. Install new thermocouple and tighten securely into gas valve.
  4. Reattach leads to terminals, usually using mini-screws.
  5. Carefully bend into proper pilot flame position.

Be sure to position the new thermocouple so the final 1/2″ is enveloped in the pilot flame. This ensures stable heat transfer for a strong, reliable voltage signal to the gas valve.

Added Safety Tips

To prevent future thermocouple failures:

  • Inspect regularly for corrosion and clean with emery cloth if needed.
  • Avoid bending leads sharply to prevent internal wire breaks.
  • Keep connections tight and free of moisture or debris.

With a simple thermocouple replacement, you can keep your trusty torpedo or garage heater running safely and reliably for years to come. Stay warm!

Get Replacement Legs For Knocked Over Mr. Heater Portables

Dyna-Glo Heater Parts Won

Got a tipped over Mr. Heater portable whose legs look worse for wear? Replacing bent or broken legs is an easy fix to get it standing upright again.

Mr. Heater’s line of portable propane heaters are designed for convenient spot heating on jobsites and in garages. Their compact size and folding legs allow them to be easily transported and positioned. But their light weight also makes them prone to getting knocked over in high traffic areas.

Repeated impacts can bend the sheet metal legs out of shape or snap them off completely. Thankfully, replacement legs are inexpensive and straightforward to install.

When To Replace Damaged Legs

Look for these signs that your portable heater legs need replacing:

  • Legs are visibly bent or deformed
  • Mounting brackets are cracked or broken
  • Heater will not sit level or wobbles
  • Legs detached completely from base

If any leg shows excessive damage, replacement is recommended. Attempting to re-bend severely deformed legs may lead to premature failure or improper fit.

Installing New Replacement Legs

Dyna-Glo Heater Parts Won

Here are the basic steps for swapping damaged legs for new:

  1. Remove any intact legs by unscrewing brackets.
  2. Unbolt damaged leg mount brackets from heater base.
  3. Bolt on new replacement leg brackets using original hardware.
  4. Attach new legs by screwing into brackets.

Be sure to examine the heater base closely for any cracks or damage. Also inspect fuel lines and valves for any leakage caused by impact. Replace any damaged components before using.

Tips for Preventing Future Damage

To help keep your new legs intact:

  • Position heater out of high traffic zones.
  • Stabilize on a flat, even surface.
  • Fold up legs for storage/transport.
  • Add weights/sandbags for extra stability.

With fresh new legs, your Mr. Heater portable will be standing tall and providing reliable spot heating for years to come. Stay cozy!

Try A New Hearthrite Heater Control Valve

Is your Hearthrite heater not firing up when you turn the dial? Before calling a service tech, inspect the gas control valve. Sticky or worn out valves are a common culprit for ignition issues in aging heaters.

The control valve regulates propane flow to the burner based on thermostat and safety sensor inputs. Like other mechanical components, valves gradually wear out over time. Replacing a faulty one with a new OEM part can often get your heater lighting again.

Signs of Failing Control Valves

Here are some telltale symptoms of a malfunctioning heater control valve:

  • Burner won’t light despite repeated sparking
  • Heater lights but shuts off soon after
  • Knob feels stuck or has limited range
  • Noticeable gas odor when attempting to light

If the safety sensors check out okay, a sticky or leaking gas control valve is likely the culprit. Time to replace it.

Replacing a Hearthrite Control Valve

Here are the basic steps for replacing a faulty heater gas valve:

  1. Turn off propane supply and allow heater to fully cool.
  2. Detach gas supply line and wiring connected to valve.
  3. Unscrew valve mounting nuts and remove old valve.
  4. Install new OEM replacement valve and tighten mounting hardware.
  5. Reconnect gas line and wires to proper terminals.

Make sure to use a factory authorized replacement part to maintain safety certifications. After installation, check for leaks by soap testing all connections.

Preventing Future Control Valve Issues

Dyna-Glo Heater Parts Won

To extend the service life of the new valve:

  • Lubricate knob and internal components yearly.
  • Protect from drips, condensation and insects.
  • Turn off propane supply when not in use.
  • Keep electrical connections tight and corrosion-free.

With a properly operating gas control valve, your aging Hearthrite heater will continue providing reliable warmth and ambiance. Stay cozy!

Adjust The Flame Sensor On Your QMark Wall Heater

Having trouble getting your Dyna-Glo heater to light or stay lit? You’re not alone. Ignition issues are common with many brands of propane and natural gas heaters, including Dyna-Glo models. The good news is that the cause is often something simple that you can fix yourself in just a few minutes. Here are 10 quick troubleshooting tips to try if your Dyna-Glo heater won’t light or stay lit:

1. Check Your Propane Tank

Make sure your propane tank isn’t empty or near-empty. Your heater may light initially but then go out once the fuel flow becomes restricted. Try swapping in a full propane tank before moving on to other troubleshooting.

2. Clean the Burner and Igniter

Dyna-Glo Heater Parts Won

Over time, spider webs, dust and debris can accumulate on the burner and prevent proper ignition. Use compressed air or a soft brush to gently clean off any buildup. Pay special attention to the igniter and any small gas ports or orifices.

3. Adjust the Air Shutter

There is often an adjustable air shutter on the burner that regulates the air-fuel mixture. Make sure it is open far enough for proper combustion, but not so far as to make the flame burn lean and go out.

4. Check for Proper Electrode Spark Gap

The igniter electrode should be properly positioned 1/8″ to 3/16″ away from the burner. If the gap is too wide or narrow, the spark may not ignite the gas. Carefully adjust the electrode if needed.

5. Replace the Igniter or Igniter Battery

The igniter electrode and wiring can wear out over time. Substitute a known-good igniter to see if that was the culprit. Also, replace the AA battery in battery-powered igniters annually.

6. Verify the Thermocouple is in the Flame

The thermocouple should be engulfed in the burner’s flame. If not, it can’t sense the heat, which signals the gas valve to remain open. Carefully bend the thermocouple into proper position.

7. Replace the Thermocouple

Faulty thermocouples are one of the most common causes of heaters not staying lit. Swap in a replacement thermocouple to see if that fixes your heater.

8.Clean or Replace Orifice and Burner

Clogged orifices or burners prevent the proper amount of gas from flowing. Use a needle or wire to clear any blockages. If damaged, replace the burner and orifice.

9. Check the Gas Regulator

Problems with the gas regulator can cause ignition issues. Confirm the regulator is set for the proper gas type and pressure. Replace if necessary.

10. Test for Gas Leaks

Leakage downstream of the gas valve could be the culprit. Spray connecitons with soapy water to check for bubbles indicating leaks. Tighten fittings or replace leaky parts as needed.

In many cases, persistence and methodically working through these troubleshooting steps will uncover the cause. But if you still can’t get your Dyna-Glo heater lighting reliably, then it may be time to enlist a professional. Licensed heating technicians have specialized tools and expertise to accurately diagnose and fix tricky ignition issues. But hopefully these 10 quick fixes will get your propane or gas heater back up and running so you can stay warm!

Swap In New Glow Warm Heater Burner Components

Dyna-Glo Heater Parts Won

Is your trusty Glo Warm heater failing to light up or having trouble staying on? Struggling to get it glowing again? Don’t despair – with a little DIY troubleshooting, you’ll likely have it firing properly in no time. Ignition problems are pretty common with propane wall heaters after seasons of use. Often the fix is as simple as replacing a small part or giving the unit a good cleaning. Here are 10 tips to try before calling in the pros:

1. Fuel Up First

An obvious first step – make sure your propane tank isn’t empty! Your heater may initially light but then sputter out as fuel flow drops off. Hook up a full tank and see if that makes the difference before moving on.

2. Blow Away Dirt and Dust

Over time, spider webs, pet hair, dust bunnies and all manner of gunk can clog up the burner ports and hinder ignition. Use compressed air or a soft brush to gently clean away debris accumulation.

3. Open the Air Shutter Wider

There’s typically an adjustable air shutter on the burner that controls the air-fuel mixture. Make sure it’s open far enough for good combustion, but not so far that the flame burns lean and weak.

4. Re-Gap the Igniter Electrodes

Dyna-Glo Heater Parts Won

The igniter’s electrode tip should be 1/8″ to 3/16″ away from the burner surface to generate a strong spark. Re-bend or adjust as needed if the gap is too large or small.

5. Install New Igniter Batteries

For battery-powered igniters, stale batteries could be the culprit. Pop in a fresh set of AAs annually for reliable ignition.

6. Reposition the Thermocouple

The thermocouple must be in the flame path to sense the heat and hold the gas valve open. Carefully bend it back into the proper position if it has shifted.

7. Replace the Thermocouple

Faulty thermocouples cause many heaters to go out repeatedly. Swapping in a new one is cheap and easy – and often solves ignition woes.

8. Upgrade Burner Components

After seasons of use, the burner, orifices and gas lines get gummed up. Install refreshed Glo Warm replacement parts for peak performance.

9. Inspect the Gas Regulator

Make sure the regulator is set for the proper gas type and pressure. If it’s damaged, replacing this inexpensive part could get your heater firing right.

10. Check for Leaks

Leaks downstream of the gas valve prevent proper ignition. Spray connections with soapy water to check for bubbles indicating leaks. Tighten or replace as needed.

With a bit of methodical troubleshooting and maybe a cheap replacement part or two, you’ll likely have your Glo Warm glowing merrily again in no time. But if these DIY tips don’t solve your ignition woes, it may be time to bring in a pro. Licensed technicians have the skills and tools to accurately diagnose any issues and get your heater up and running for another cozy season!